Validation of viewstate MAC failed. If this application is hosted by a Web Farm or cluster, ensure that <machineKey> configuration specifies the same validationKey and validation algorithm. AutoGenerate cannot be used in a cluster.

Validation of viewstate MAC failed. If this application is hosted by a Web Farm or cluster, ensure that <machineKey> configuration specifies the same validationKey and validation algorithm. AutoGenerate cannot be used in a cluster.

This error is usually caused by the asp.net worker process or the server recycling. By default, ASP.NET encrypts the viewstate using an Autogenerated Key when the process spins up. The problem comes when a client (browser) sends the request with a viewstate encrypted with the key generated by another worker process. Since the key is different, ASP.NET will not be able to decrypt the viewstate and it will throw the above error.

There are several ways to get around this problem:

1) Host your site on a server where the application pools never recycle! Obviously, this is impossible.

2) Disable ViewstateMac by putting this “enableViewStateMac="false"” in your web.config. This approach is not 100% secure.

3) Configure ASP.NET to not use Auto-Generated Key but rather a predefined key. This is the preferred method.

To do this, follow these steps:

a) Either build your own Key Generator (http://support.microsoft.com/kb/313091/EN-US/)or use this tool (https://codewithshadman.com/machine-key-generator/). I highly recommend you use the online tool. So assuming you will use the online tool:

b) In the online tool, simply click on “Generate”.

c) Copy the content in the textbox into your site’s web.config file. The machineKey node should be within <system.web>

eg.

<?xml version="1.0"?>

<configuration>
<appSettings/>
<connectionStrings/>
<system.web>
<machineKey
validationKey="2EEA416CEFC6D6BE856ED57B97FB9CA7DFACE17C073125949A1D682C80A44BB2A
D887DDDC13DBFB0954F1000FEE5757E99693F222F8E28CAA2E6DAB8C4F99E0C"
decryptionKey="877478B2F33A74226ABEF55FDCC1A76E43F1BBEA6241A592"
validation="SHA1" />
<compilation debug="false"/>
<authentication mode="Windows"/>
<pages enableViewStateMac="true"/>
</system.web>
</configuration>

For more information on viewstate troubleshooting, see http://support.microsoft.com/default.aspx?scid=kb;EN-US;829743
  • 69 کاربر این را مفید یافتند
آیا این پاسخ به شما کمک کرد؟

مقالات مربوطه

PHP send mail with SMTP Authentication

<?php require_once "Mail.php";   $from = "XXXXXX@yourDOMAIN.com"; $to =...

ASP.NET Application Error: An ASP.NET setting has been detected that does not apply in Integrated managed pipeline mode.

Why this error occur? It occurs as the application is not compatible with "Integrated Pipeline...

Disable Directory Browsing or Listing in PLESK

Directory listing will be disabled. Step 1:Login to Plesk Step 2:Goto Domains -> Domain Name...

I got 500 Error when viewing my Site ?

This normally happens because you turn on the Friendly Error on your IE. By default, IE always...

Mailenable Component - Mail Code

Mailenable Component - Mail Code <%@ Language=VBScript %> <% Dim oMail Set oMail =...